Improving Lives Through Science

Login | Register

Class II Biological Safety Cabinet

ProductsBiological Safety CabinetClass II BSC › Airstream® Class II Type B2 (Total Exhaust) Biosafety Cabinets

Airstream® Class II Type B2 (Total Exhaust) Biosafety Cabinets

AB2-_S_

Airstream® Class II Type B2 (Total Exhaust) Biosafety Cabinets

Airstream® Class II Type B2 Biosafety Cabinets (AB2) provide product, operator and environmental protection and are suitable for work with trace amounts of toxic chemicals and agents assigned to biological safety levels I, II or III. In a Class II Type B2 cabinet, all inflow and downflow air is exhausted after HEPA/ULPA filtration to the external environment without recirculation across the work surface.

*This cabinet requires an external blower

Features

Sentinel™ Silver Microprocessor Control system

  • Displays basic parameters such as airflow on one screen
  • Has audible and visual alarms

Esco Dynamic Chamber

  • This plenum design delivers quiet and uniform airflow

Filtration system

  • Long Life ULPA supply filter
  • HEPA exhaust filter

Fail-safe system

  • Fan automatically shuts down in cases of exhaust failure to ensure operator’ safety

Single-piece Internal work zone

  • Large radius for easy cleaning
  • Eliminates welded joints to prevent accumulation of contaminants

Isocide™ Antimicrobial Powder Coating

  • Eliminates 99.9% of surface bacteria within 24 hours of exposure

Models

Item CodeModel CodeDescription
220-240 VAC, 50 Hz
2010274AB2-3S1Airstream® Class II, B2 Biological Safety Cabinet, 3ft/0.9m
2010284AB2-4S1Airstream® Class II, B2 Biological Safety Cabinet, 4ft/1.2m
2010294AB2-5S1Airstream® Class II, B2 Biological Safety Cabinet, 5ft/1.5m
2010304AB2-6S1Airstream® Class II, B2 Biological Safety Cabinet, 6ft/1.8m
110-120 VAC, 60 Hz
2010278AB2-3S2Airstream® Class II, B2 Biological Safety Cabinet, 3ft/0.9m
2010288AB2-4S2Airstream® Class II, B2 Biological Safety Cabinet, 4ft/1.2m
2010298AB2-5S2Airstream® Class II, B2 Biological Safety Cabinet, 5ft/1.5m
2010308AB2-6S2Airstream® Class II, B2 Biological Safety Cabinet, 6ft/1.8m
220-240 VAC, 60 Hz
2010281AB2-3S3Airstream® Class II, B2 Biological Safety Cabinet, 3ft/0.9m
2010291AB2-4S3Airstream® Class II, B2 Biological Safety Cabinet, 4ft/1.2m
2010301AB2-5S3Airstream® Class II, B2 Biological Safety Cabinet, 5ft/1.5m
2010311AB2-6S3Airstream® Class II, B2 Biological Safety Cabinet, 6ft/1.8m

Accessories

Item CodeModel CodeDescription
5170251UV-15AUV Lamp for 2ft, 3ft Cabinets and AC3-4B
5170255UV-30AUV Lamp for 4ft, 5ft, 6ft Cabinets except AC3-4B
Service Fixtures
5170410SF-1G20European Style Service Fixture with 20mm Thread Length - Gas
5170457SF-1V20European Style Service Fixture with 20mm Thread Length - Vacuum
5170503SF-1N20European Style Service Fixture with 20mm Thread Length - Nitrogen
5170502SF-1A20European Style Service Fixture with 20mm Thread Length - Air
5170458SF-1W20European Style Service Fixture with 20mm Thread Length - Water
5170504SF-2U22American Style Service Fixture with 22mm Thread Length - Universal
5170026CU-PipeCopper Piping for Service Fixture - Must be Factory Installed
Support Stands
SPC-_A0 Gen2Support Stand with Caster Wheels (Height 28”)
SPC-_B0 Gen 2Support Stand with Caster Wheels (Height 34”)
SAL-_A0 Gen 2Support Stand with Leveling Feet - I (Height 28”)
SAL-_B0 Gen 2Support Stand with Leveling Feet - I (Height 34”)
IV Bars
5170276IV-955IV Bar 955 mm
5170277IV-1260IV Bar 1260 mm
5170278IV-1565IV Bar 1565 mm
5170279IV-1870IV Bar 1870 mm
Others
5170353ABBV-12PAnti Blowback Valve, 12" diameter
5170105B2-DamperManual Volumetric Exhaust Damper, 12"

Catalogs and Brochures

Esco Class II BSC Tri-fold brochure

Guide to Biosafety and Biological Safety Cabinets

Airstream® Class II Type B2 BSC Brochure