Improving Lives Through Science

Login | Register

Sample Monitoring Software

ProductsSample Monitoring Software › PROtect Gen 2

PROtect G2 T0

PROtect G2 T0

PROtect G2 T1

PROtect G2 T1

PROtect G2 T2

PROtect G2 T2

PROtect G2 T3

PROtect G2 T3

PROtect G2 Digital

PROtect G2 Digital

PROtect G2 TH1

PROtect G2 TH1

PROtect G2 U

PROtect G2 U

Micro Gateway Ethernet

Micro Gateway Ethernet

Data Log

Data Log

Graph

Graph

PROtect Gen 2

Esco PROtect Generation 2 monitoring system includes radio frequency recorders that can be connected to any brand of temperature-controlled equipment. These recorders automatically send data to a central server to monitor temperature and other parameters and send real-time alerts to users. Esco PROtect Generation 2 complies with ISO 17025, GMP, and GLP requirements.

System Requirements

Operating system:

  • Windows Server 2012 R2 / Windows Server 2016 / Windows 10 / Windows Server 2019
  • IIS Web Server version 8 minimum
  • SQL Server Express 2014 or higher version
  • Microsoft Framework.NET 4.7.2 or higher version
  • Access to SMTP server for email alerts
  • Access to a MultiTech GSM Router for text messages alerts

Server configuration:

  • Processor: 2 cores minimum 2,6GHz
  • RAM: 8 GB (4 GB is the minimum required for a small installation, ex: 10 units)
  • Hard disk: 4 GB for the installation + 10 GB maximum for stored data.
    (Microsoft SQL Server Express manages 1 physical processor, 1 GB RAM and 10 GB DATA storage)

Customer’s Network:

  • Allow TCP/IP communications on Port 13251 (Incoming traffic) in case of single server installation (can be changed in MySirius Configuration)
  • Incoming/Outgoing traffic: in case of multi-server installation. The Services and the IIS Web server should have access to the Dispatcher.
  • Allow TCP/IP communications on Port 13252 (Incoming traffic) for configurations with LoRa devices (can be changed in MySirius Configuration)
  • Allow customer SMTP server access for email alerts sending
  • Allow communication with a Multitech GSM router for text message alerts sending

Features

Suitable for monitoring equipment:

  • with few sensors
  • spread on a wide territory
  • in need of real-time data transportation

Various available sensors to choose from for the monitoring of various parameters e.g., temperature, humidity, pressure, gas, door opening

The sensors are equipped with an internal memory that can record up to 10,000 data points

Low power consumption with battery life that can last up to 4 years

Compatible with any brand of equipment

Models

Item CodeModel Code
868 MHz
1081482Protect G2 t0, 868 MHz, -35°C to +85°C, temperature probe without LCD display
1081483Protect G2 t1, 868 MHz, -30°C to +70°C, temperature probe with LCD display & light sensor
1081484Protect G2 t2, pt100, 868 MHz, -50°C to +105°C, moduled probe cl.A ø5x20mm, with 30cm cable flat sentoprene
1081485Protect G2 t2, pt100, 868 MHz, -50°C to +105°C, moduled probe cl.A ø5x20mm, with 3m cable flat sentoprene
1081534Protect G2 t2i, pt100 868MHz, -50°C to +105°C, moduled probe cl.A ø5x20mm, with 3m cable flat sentoprene for incubator
1081486Protect G2 t3, pt100, 868 MHz, -200°C to +0°C, stainless steel probe ci.A ø3x20mm, with 0.5M teflon cable ø2.9mm
1081487Protect G2 t3, pt100, 868 MHz, -200°C to +0°C, stainless steel probe ci.A ø3x20mm, with 6m teflon cable ø2.9mm
1081489Protect G2 th1, 868 MHz, -30°C to +70°C / 0-100%RH, ambient temperature and humidity probe
1081490Protect G2 universal, 868 MHz, for pt100 - on/off - count 4 - 20ma sensor
1081491Protect G2 digital, 868 MHz, with binder connector without sensor
1081492Protect G2 reference pt100, 868 MHz, -196°C to +150°C, stainless steel probe ci.A ø3x20mm, with 3m teflon cable ø2.9mm
1081556Protect G2 tester for 868MHz gateway, excluding batteries
915 MHz
1081493Protect G2 t0, 915 MHz, -40°C to +85°C, temperature probe without LCD display
1081494Protect G2 t1, 915 MHz, -30°C to +70°C, temperature probe with LCD display & light sensor
1081495Protect G2 t2, pt100, 915 MHz, -50°C to +105°C, moduled probe cl.A ø5x20mm with 30cm cable flat sentoprene
1081496Protect G2 t2, pt100, 915 MHz, -50°C to +105°C, moduled probe cl.A ø5x20mm with 3m cable flat sentoprene
1081535Protect G2 T2i, pt100, 915MHz, -50 to +105°C, moduled probe cl.A ø5x20mm with 3m cable flat sentoprene for incubator
1081497Protect G2 t3, pt100, 915 MHz, -200°C to +0°C, stainless steel probe ci.A ø3x20mm, with 0.5M teflon cable ø2.9mm
1081498Protect G2 t3, pt100, 915 MHz, -200°C to +0°C, stainless steel probe ci.A ø3x20mm, with 6m teflon cable ø2.9mm
1081499Protect G2 th1, 915 MHz, -30°C to +70°C / 0-100%RH, ambient temperature and humidity probe
1081500Protect G2 universal, 915 MHz, for pt100 - on/off - count 4 - 20ma sensor
1081501Protect G2 digital, 915 MHz, with binder connector without sensor
1081502Protect G2 reference pt100, 915 MHz, -196°C to +150°C, stainless steel probe ci.A ø3x20mm with 3m teflon cable ø2.9mm
1081557Protect G2 tester for 915MHz gateway, excluding batteries
868 MHz
1081503Micro gateway ethernet 868 MHz
1081504Micro gateway 4G 868 MHz
1081552Gateway PROtect G2, ethernet Lora® gateway 868, with 3db external antenna 20cm
1081553Gateway PROtect G2, 4G/eth Lora® gateway 868, with 3db external antenna 20cm (excluding subscription)
915 MHz
1081505Micro gateway ethernet 915 MHz
1081506Micro gateway 4G 915 MHz
1081554Gateway PROtect G2, ethernet Lora® gateway 915, with 3db external antenna 20cm
1081555Gateway PROtect G2, 4G/eth Lora® gateway 915, with 3db external antenna 20cm (excluding subscription)

Accessories

Item CodeModel Code
1081536Wall mounting bracket pack @10pcs, for PROtect G2 & PROtect mini
1081075Protect battery lithium 3.6V (only for sea and land transport)
1081537Battery covers pack @10pcs, for PROtect G2, & PROtect mini, wall mounting, 2x4-20ma output
1081538Protective housing, for PROtect G2, duct mounting, 4-20ma output
1081539TH transmitter (15-35vcc / 5ma), -40 +60°C/0-100 %RH, output 2x0-1v
1081540TH transmitter (15-35vcc / 5ma), -30 +70°C/0-100 %RH, output 2x0-1v
1081541Precision ambient TH transmitter, -40 +60°C/0-100 %RH, with power supply and 1.5m cable(round)
1081542Precision industrial TH transmitter, configurable from -100 to +200°C/0-100 %RH
1081543CO₂ transmitter, 0-20 %
1081544Flat cable for CO₂ PRObe
1081545CO₂ PRObe holder
1081546O₂ transmitter (8-33vcc / 24ma) 4-20ma output, 0-25%
1081547Atmospheric pressure transmitter, 800-1100hpa 4-20ma (8-35vdc), power supply & universal adapter to be ordered separately
1081548DP transmitter (±30/50/100 pa) 24 VDC with 2m pipe, with 50 cm cable
1081549Lux transmitter 0-20 klux 10-40 VDC, saline or corrosive conditions, universal adapter to be ordered separately
1081550Door contact for thermostatic cabinet
1081551Door contact for cold room (sliding door)
1081488GSM router ethernet for SMS
Subscription
1081507Cloud annual subscription, basic, up to 10 measurements points
1081508Cloud annual subscription, basic, up to 100 measurements points
1081509Cloud annual subscription, plus, up to 10 measurements points
1081510Cloud annual subscription, plus, up to 100 measurements points
1081511Cloud annual subscription, PRO, up to 10 measurements points
1081512Cloud annual subscription, PRO, up to 100 measurements points
1081517Server system PRO, up to 100 measurements
1081608Server system PRO, up to 500 measurements
1081558Pack of 100 SMS zone 1, (France/USA/Canada/China/UAE/Saudi Arabia)
1081559Pack of 500 SMS zone 1, (France/USA/Canada/China/UAE/Saudi Arabia)
1081560Pack of 1000 SMS zone 1, (France/USA/Canada/China/UAE/Saudi Arabia)
1081561Pack of 100 SMS zone 2, (Europe/Martinique/Guadeloupe/Réunion)
1081562Pack of 500 SMS zone 2, (Europe/Martinique/Guadeloupe/Réunion)
1081563Pack of 1000 SMS zone 2, (Europe/Martinique/Guadeloupe/Réunion)
1081564Pack of 100 SMS zone 3, (rest of world)
1081565Pack of 500 SMS zone 3, (rest of world)
1081566Pack of 1000 SMS zone 3, (rest of world)

Catalogs and Brochures

PROtect Gen 2 and Mini Brochure