Improving Lives Through Science

Login | Register

Class II Biological Safety Cabinet

ProductsBiological Safety CabinetClass II BSC › Airstream® NS (S-series) G4 Class II Type A2 Biological Safety Cabinet

Airstream® NS G4 Class II Type A2 Biological Safety Cabinet

AC2-S-NS G4

Airstream® NS (S-series) G4 Class II Type A2 Biological Safety Cabinet

Introducing Airstream® NS (S-series) G4 Class II Type A2 Biosafety Cabinet.

The new BSC with Centurion Touchscreen controller is NSF-certified with standby height that easily activates standby mode, an ergonomic work zone that is comprised of bright illumination using industry-leading dimmable LED combined with raised, durable, stainless-steel armrest. It also comes with wider model options offering stainless steel (S-series) and glass (E-series) side wall variants.

The Airstream® NS (S-series) G4 incorporates greener features, ensuring a more sustainable and environmentally friendly operation. With its compact size and advanced features, this biosafety cabinet offers an unparalleled level of convenience and safety, making it the ideal choice for laboratories and research facilities.

Features

Centurion Touchscreen Controller

  • Intuitive, comprehensive, and easy-to-understand
  • Virtually comprehensible safety information and cabinet alarms via 3D BSC diagram
  • Defined details of alarm types with clear instructions for proper intervention
  • Centered and angled down for easy reach & viewing
  • Selectable Quickstart mode for fast operation

Dimmable LED

  • Adjustable work zone brightness
  • Ideal light intensity of 1200 lux
  • Saves energy and optimizes work comfort

Ergonomic Features

  • 8” sash opening
  • Frameless, shatterproof, and UV-absorbing tempered glass

Tray support beams and holder

  • Support beams for less vibration and holder for easy drain pan cleaning

USB Port and Remote Modbus

  • USB port to access cabinet data log and BMS connectivity
  • Newly integrated Remote Modbus feature for users to securely access the cabinet remotely from external devices.

Cabinet Construction

  • S-Series:
    • Stainless steel side walls with side capture zones and negative pressure to optimize containment
    • Single-piece work tray, spill retaining and easy to clean

Green Product

  • Equipped with energy-efficient DC ECM that allows up to 70% energy savings vs AC motor
  • Extremely low energy consumption with 184 watts (4 ft unit)
  • Standby mode allows reduced power consumption

ULPA Filter

  • 10x filtration efficiency compared to the HEPA filter
  • Creates ISO Class 3 work zone instead of industry-standard, ISO Class 5
  • Same 10 years filter life and replacement cost as HEPA filters

*99.999% at 0.1 to 0.3 micron, ULPA as per IEST-RP-CC001.3 USA
*99.999% at MPPS, H14 as per EN 1822 EU

Isocide™ Antimicrobial Powder Coating

  • Eliminates 99.9% of surface bacteria within 24 hours of exposure

Models

Item Code Model Code Description
220-240 VAC, 50/60 Hz (S-Series: Stainless steel side walls, single piece work tray)
2011756 AC2-2S8-NS G4 8” Airstream® NS G4 Class II Type A2 Biological Safety Cabinet, 2ft/0.6m, 8-inch opening
2011428 AC2-3S8-NS G4 8” Airstream® NS G4 Class II Type A2 Biological Safety Cabinet, 3ft/0.9m, 8-inch opening
2011604 AC2-3S8-NS G4 10” Airstream® NS G4 Class II Type A2 Biological Safety Cabinet, 3ft/0.9m, 10-inch opening
2011404 AC2-4S8-NS G4 8” Airstream® NS G4 Class II Type A2 Biological Safety Cabinet, 4ft/1.2m, 8-inch opening
2011605 AC2-4S8-NS G4 10” Airstream® NS G4 Class II Type A2 Biological Safety Cabinet, 4ft/1.2m, 10-inch opening
2011430 AC2-5S8-NS G4 8” Airstream® NS G4 Class II Type A2 Biological Safety Cabinet, 5ft/1.5m, 8-inch opening
2011606 AC2-5S8-NS G4 10” Airstream® NS G4 Class II Type A2 Biological Safety Cabinet, 5ft/1.5m, 10-inch opening
2011432 AC2-6S8-NS G4 8” Airstream® NS G4 Class II Type A2 Biological Safety Cabinet, 6ft/1.8m, 8-inch opening
2011607 AC2-6S8-NS G4 10” Airstream® NS G4 Class II Type A2 Biological Safety Cabinet, 6ft/1.8m, 10-inch opening
110-130 VAC, 50/60 Hz (S-Series: Stainless steel side walls, single piece work tray)
2011757 AC2-2S9-NS G4 8” Airstream® NS G4 Class II Type A2 Biological Safety Cabinet, 2ft/0.6m, 8-inch opening
2011429 AC2-3S9-NS G4 8” Airstream® NS G4 Class II Type A2 Biological Safety Cabinet, 3ft/0.9m, 8-inch opening
2011926 AC2-3S9-NS G4 10” Airstream® NS G4 Class II Type A2 Biological Safety Cabinet, 3ft/0.9m, 10-inch opening
2011403 AC2-4S9-NS G4 8” Airstream® NS G4 Class II Type A2 Biological Safety Cabinet, 4ft/1.2m, 8-inch opening
2011927 AC2-4S9-NS G4 10” Airstream® NS G4 Class II Type A2 Biological Safety Cabinet, 4ft/1.2m, 10-inch opening
2011431 AC2-5S9-NS G4 8” Airstream® NS G4 Class II Type A2 Biological Safety Cabinet, 5ft/1.5m, 8-inch opening
2011928 AC2-5S9-NS G4 10” Airstream® NS G4 Class II Type A2 Biological Safety Cabinet, 5ft/1.5m, 10-inch opening
2011433 AC2-6S9-NS G4 8” Airstream® NS G4 Class II Type A2 Biological Safety Cabinet, 6ft/1.8m, 8-inch opening
2011929 AC2-6S9-NS G4 10” Airstream® NS G4 Class II Type A2 Biological Safety Cabinet, 6ft/1.8m, 10-inch opening

Accessories

Item Code Model Code Description
5170251 UV-15A-L UV Lamp for 2 ft and 3ft Cabinets
5170255 UV-30A-L UV Lamp for 4ft, 5ft, 6ft Cabinets
5170071 EO-GFCI GFCI Outlet x 2 (For -9 models)
  EO _ Electrical Outlet (Direct Mounted) x 2 (For -8 models)
IV Bars
5170498 IV-605 IV Bar 605 mm
5170499 IV-910 IV Bar 910 mm
5170231 IV-1215 IV Bar 1215 mm
5170500 IV-1520 IV Bar 1520 mm
5170501 IV-1825 IV Bar 1825 mm
Support Stands
5131339 STA-2A0 Support Stand Telescoping with Leveling Feet and Castors (28” to 36”) for 2ft cabinets
5131340 STA-3A0 Support Stand Telescoping with Leveling Feet and Castors (28” to 36”) for 3ft cabinets
5131341 STA-4A0 Support Stand Telescoping with Leveling Feet and Castors (28” to 36”) for 4ft cabinets
5131427 STA-5A0 Support Stand Telescoping with Leveling Feet and Castors (28” to 36”) for 5ft cabinets
5131389 STA-6A0 Support Stand Telescoping with Leveling Feet and Castors (28” to 36”) for 6ft cabinets
Service Fixtures
5170410 SF-1G20 European Style Service Fixture with 20mm Thread Length - Gas
5170457 SF-1V20 European Style Service Fixture with 20mm Thread Length - Vacuum
5170502 SF-1A20 European Style Service Fixture with 20mm Thread Length - Air
5170503 SF-1N20 European Style Service Fixture with 20mm Thread Length - Nitrogen
5170458 SF-1W20 European Style Service Fixture with 20mm Thread Length - Water
5170504 SF-2U22 American Style Service Fixture with 22mm Thread Length - Universal
Exhaust Collars
5171229 ECO-FLAP-LA2/AC2-2 G4 Thimble Exhaust Collar for AC2-2-NS G4
5171097 ECO-FLAP-LA2/AC2-3 G4 Thimble Exhaust Collar for AC2-3-NS G4
5171098 ECO-FLAP-LA2/AC2-4 G4 Thimble Exhaust Collar for AC2-4-NS G4
5171099 ECO-FLAP-LA2/AC2-5 G4 Thimble Exhaust Collar for AC2-5-NS G4
5171100 ECO-FLAP-LA2/AC2-6 G4 Thimble Exhaust Collar for AC2-6-NS G4
Exhaust Accessories
5170129 B2-ABBV1 Anti-blowback Valve 10 inches
5170354 ABBV-10S Anti-blowback Valve 10 inches (304 Stainless Steel)
5170104 B2-DAMPER Manual Volumetric Exhaust Damper
VHP IN Ports
5260340 Decon cover with VHP IN PORT AC2-2 G4 Decon cover with VHP IN PORT for AC2-2-NS G4
5260329 Decon cover with VHP IN PORT AC2-3 G4 Decon cover with VHP IN PORT for AC2-3-NS G4
5260330 Decon cover with VHP IN PORT AC2-4 G4 Decon cover with VHP IN PORT for AC2-4-NS G4
5260331 Decon cover with VHP IN PORT AC2-5 G4 Decon cover with VHP IN PORT for AC2-5-NS G4
5260332 Decon cover with VHP IN PORT AC2-6 G4 Decon cover with VHP IN PORT for AC2-6-NS G4
VHP OUT Ports (WITHOUT exhaust collar)
5075192 VHP-OUT TOP BOX AC2-2 G4 VHP OUT TOP BOX For Cabinet WITHOUT Exhaust collar installed (1-inch diameter) for AC2-2-NS G4
5074983 VHP-OUT TOP BOX LA2-3-G4 VHP OUT TOP BOX For Cabinet WITHOUT Exhaust collar installed (1-inch diameter) for AC2-3-NS G4
5074984 VHP-OUT TOP BOX LA2-4-G4 VHP OUT TOP BOX For Cabinet WITHOUT Exhaust collar installed (1-inch diameter) for AC2-4-NS G4
5074985 VHP-OUT TOP BOX LA2-5-G4 VHP OUT TOP BOX For Cabinet WITHOUT Exhaust collar installed (1-inch diameter) for AC2-5-NS G4
5074986 VHP-OUT TOP BOX LA2-6-G4 VHP OUT TOP BOX For Cabinet WITHOUT Exhaust collar installed (1-inch diameter) for AC2-6-NS G4
VHP OUT Ports (WITH exhaust collar)
5171230 VHP-ECO/OUT AC2-2 G4 VHP OUT PORT For Cabinet WITH Exhaust collar installed (1-inch diameter) for AC2-2-NS G4
5171111 VHP-ECO/OUT LA2-3-G4 VHP OUT PORT For Cabinet WITH Exhaust collar installed (1-inch diameter) for AC2-3-NS G4
5171112 VHP-ECO/OUT LA2-4-G4 VHP OUT PORT For Cabinet WITH Exhaust collar installed (1-inch diameter) for AC2-4-NS G4
5171113 VHP-ECO/OUT LA2-5-G4 VHP OUT PORT For Cabinet WITH Exhaust collar installed (1-inch diameter) for AC2-5-NS G4
5171114 VHP-ECO/OUT LA2-6-G4 VHP OUT PORT For Cabinet WITH Exhaust collar installed (1-inch diameter) for AC2-6-NS G4
Others
5170127 MEWREST Arm Rest Padding
5170492 FT-REST Foot Rest
9010179   IQ/OQ Protocol

Catalogs and Brochures

Esco Class II BSC Tri-fold brochure

Guide to Biosafety and Biological Safety Cabinets

Airstream® NS G4 Brochure

Airstream® NS G4 Spanish Brochure

Airstream® NS G4 US Brochure